UMG 508 (Uh 95..240Vac/80-340Vdc) | Power analyser

Welke lengte heeft u nodig?
/
U heeft 0 stuks nodig voor 0 euro incl. BTW
UMG 508 (Uh 95..240Vac/80-340Vdc)
Ask for quotationAdd to wish list
 Stock: 16 piece(s)
 Log in to see price
Add to favorites
  • Product description and specifications
  • Documents
  • Ask a Question
  • Related products

Barcode

Product description

The UMG 508 is the predecessor of the Janitza UMG 509-PRO.

Voltage sags, transients, and harmonics are not just disturbances; in modern electrical installations, they can cause serious problems. These disruptions can lead to unforeseen outages and costly repairs. The Janitza UMG 509-PRO Power Analyser goes beyond just identifying these issues; it also proactively alerts users through notifications.

The UMG 509-PRO is more than a standard power analyser. It is a multifunctional device that includes features such as a power quality analyser, kWh-meter, IP gateway, datalogger, and a web server, all in one robust housing.

Thanks to the integrated web interface of the UMG 509-PRO, users have real-time insight into the power quality of their systems. This interface is user-friendly and can be easily accessed from various devices, from desktops to smartphones. Automatic reports, tailored to current standards, ensure a quick identification and resolution of energy problems.

Technically, the UMG 509-PRO offers Fourier analyses up to the 63rd order and records more than 1500 variables every 200 milliseconds. Continuous sampling of all voltage and current channels at 20kHz ensures accurate measurements.

With support for protocols such as RS485 (Modbus RTU) and Ethernet, the UMG 509-PRO can be seamlessly integrated into existing systems.

Main features of the UMG 509-PRO Power Analyser:
  • Effective detection of consumption, disturbances, and power quality
  • Identifies voltage sags, transients, and harmonics up to the 63rd order
  • Notifications via the web interface
  • Multifunctional: Power Quality analyser, kWh-meter, IP gateway, datalogger, and web server all in one
  • Accessible integrated web interface via various devices
  • Automatic Power Quality reporting according to current standards
  • Continuous monitoring of ground fault currents, eliminating the need for periodic insulation tests
  • Recording of short interruptions, transients, and peaks
  • Extensive technical capabilities, including Fourier analysis and a high sampling rate
  • Smooth integration thanks to various communication protocols

Documents

Specifications

SeriesUMG 508
Communication interface

A communication interface is a physical or software-based connection between two systems or devices, enabling them to communicate and exchange data.

Communication interfaceEthernet
RS485
Profibus
Digital inputs8
Digital outputs5
Communication protocol

A communication protocol is a set of rules and standards used to enable the exchange of data between different devices or systems.

Communication protocolModbus RTU
Modbus TCP
Profibus DP
Memory

Janitza measuring instruments are equipped with memory, allowing measurement values to be stored in memory for extended periods of time.

Memory256 MB
Auxiliary voltage

Auxiliary voltage is the additional voltage required to supply a device with power for proper operation and measurements.

Auxiliary voltage95...240 VAC
80...340 VDC
User interfaceColour screen
Web interface
Harmonics

A harmonic is a frequency that is an integer multiple of the fundamental frequency. The fundamental frequency is the lowest (natural) frequency that a system exhibits by default. A natural frequency of a system is a frequency that the system can inherently exhibit.

HarmonicsU/I to 40th order
Event registrationDips(ms)
Peaks
Transients(us)
Reportso.a. kWh / voltage quality
BrandJanitza
CategoryPower analysers
EAN Code4251861100330
Product codeJA200495
Supplier code5221001
Unitst

Related products

UMG 509-PRO  UH= 95-240V AC (Fortop) | Power analyser
 Stock: 187 piece(s)
 Log in to see price
Product code: JA200412
UMG 509-PRO (Uh 48..110Vac/24..150Vdc) | Power analyser
 Stock: 3 piece(s)
 Log in to see price
Product code: JA200222
GridVis Expert, basic package with 10 items | Software
 Available: 10
 Log in to see price
Product code: JA901943
GridVis Expert, basic package with 25 items | Software
 Available: 10
 Log in to see price
Product code: JA901944
GridVis Expert, basic package with 50 items | Software
 Available: 10
 Log in to see price
Product code: JA901945
GridVis Standard, basic package with 10 items | Software
 Available: 10
 Log in to see price
Product code: JA901920
GridVis Standard, basic package with 25 items | Software
 Available: 10
 Log in to see price
Product code: JA901921